71M6543F/71M6543G Data Sheet
2.3.4
Meter Equations
The 71M6543 provides hardware assistance to the CE in order to support various meter equations. This
assistance is controlled through I/O RAM field EQU[2:0] (equation assist, I/O RAM 0x2106[7:5]) . The
Compute Engine (CE) firmware configurations can implement the equations listed in Table 7 . EQU[2:0]
specifies the equation to be used based on the meter configuration and on the number of phases used for
metering.
Table 7: Inputs Selected in Multiplexer Cycles
EQU[2:0]*
Description
Wh and VARh formula
Element 0 Element 1 Element 2
Recommended
Multiplexer Sequence
2
3
4
5
2-element, 3-W, 3 φ Delta
2-element, 4-W, 3 φ Delta
2-element, 4-W, 3 φ Wye
3-element, 4-W, 3 φ Wye
VA · IA
VA(IA-IB)/2
VA(IA-IB)/2
VA · IA
VB · IB
VC ·IC
VB(IC-IB)/2
VB · IB
N/A
N/A
N/A
VC · IC
IA VA IB VB
IA VA IB VB IC VC
IA VA IB VB IC VC
IA VA IB VB IC VC (ID)
Note:
* Only EQU[2:0] = 5 is supported by the currently available CE code versions for the 71M6543. Contact
your local Maxim representative for CE codes that support equations 2, 3, and 4.
2.3.5
Real-Time Monitor (RTM)
The CE contains a Real-Time Monitor (RTM), which can be programmed to monitor four selectable XRAM
locations at full sample rate. The data from the four monitored locations are serially output to the TMUXOUT
pin via the digital output multiplexer at the beginning of each CE code pass. The RTM can be enabled and
disabled with RTM_E (I/O RAM 0x2106[1]) . The RTM output clock is available on the TMUX2OUT pin. Each
RTM word is clocked out in 35 cycles and contains a leading flag bit. See Figure 8 for the RTM output
format. RTM is low when not in use.
CK32
MUX_SYNC
MUX_STATE
CKTEST
S
RTM
0
1
30
31
0
1
30
31
0
1
30
31
0
1
30
31
FLAG
FLAG
FLAG
FLAG
RTM DATA0 (32 bits)
RTM DATA1 (32 bits)
RTM DATA2 (32 bits)
RTM DATA3 (32 bits)
Figure 8: RTM Timing
2.3.6
Pulse Generators
The 71M6543 provides four pulse generators, VPULSE, WPULSE, XPULSE and YPULSE. The XPULSE
and YPULSE generators are used by standard CE code to output CE status indicators, for example the
status of the sag detection, to DIO pins. All pulses can be configured to generate interrupts to the MPU.
The polarity of the pulses may be inverted with PLS_INV (I/O RAM 0x210C[0]) . When this bit is set, the
pulses are active high, rather than the more usual active low. PLS_INV inverts all the pulse outputs.
The function of each pulse generator is determined by the CE code and the MPU code must configure the
corresponding pulse outputs in agreement with the CE code. For example, standard CE code produces a
mains zero-crossing pulse on XPULSE and a SAG pulse on YPULSE.
26
v2
相关PDF资料
71M6545-IGT/F IC ENERGY METERING
720-10007-00300 CBL D-SUB 9PIN FMAL-25PIN FML 3M
720-10010-00025 CBL DSUB 9PIN FML-25PIN MAL .25M
720-10020-00300 CBL DSUB 9PIN FML-9PIN MALE 3M
720-10021-00300 CBL DSUB 9PIN FML-9PIN FEMAL 3M
72231-0881 8 POS T/P SHLD 4 GR ASSY
7250B PANEL KIT BOTTOM FOR R-1220 CASE
731-10061-00200 CBL DSUB HD 15FEMAL-15MALE 2.0M
相关代理商/技术参数
71M6543F-IGTR/F 功能描述:计量片上系统 - SoC Precision Energy Meter IC RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel
71M6543FT-IGT/F 制造商:Maxim Integrated Products 功能描述:ENERGY METER ICS - Rail/Tube
71M6543FT-IGTR/F 制造商:Maxim Integrated Products 功能描述:3-PHASE SOC, 64KB FLASH, PRES TEMP SENSOR - Tape and Reel
71M6543G 制造商:MAXIM 制造商全称:Maxim Integrated Products 功能描述:Selectable Gain of 1 or 8 for One Current Energy Meter ICs Metrology Compensation
71M6543GH 制造商:未知厂家 制造商全称:未知厂家 功能描述:电表IC
71M6543GHT-IGT/F 制造商:Maxim Integrated Products 功能描述:3-PHASE, 128KB, PRES TEMP SENSOR, HI PREC - Bulk
71M6543GHT-IGTR/F 制造商:Maxim Integrated Products 功能描述:3-PHASE, 128KB, PRES TEMP SENSOR, HI PREC - Tape and Reel
71M6543G-IGT/F 功能描述:计量片上系统 - SoC Precision Energy Meter IC RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel